There are offline or missing virtual drives with preserved cache.

2024年 2月 21日 57.0k 0

问题场景:

RAID0磁盘故障,更换磁盘后重启OS时发现不能正常引导进入OS,报错如下:

AVAGO MeGaRAID SAS-MFI BIOS

Version 6.31.03.0 (Build January 25,2016)Copyright(c) 2016 AUAG0 TechnologiesHA -0(Bus 1 Dev 0) SAS3108FW package: 24.15.0-0016

There are offline or missing virtual drives with preserved cache.

Please check the cables and ensure that all drives are present.

Press any key to enter the configuration utility.

解决方法:

服务器重启默认进入以下页面选择 SAS3108(Bus 0x01, Dev 0X00) 按F2

按F2之后选择——
Manage Preserved Cache——
选中之后回车进去然后按——
discard the cache

按完之后会提示YES or NO 选择YES

Ctrl+Alt+Del 重启服务器即可


附:DELL官方对此问题的一些说明:

Error Message:

There are offline or missing virtual drives with preserved cache.

Please check the cables and ensure that all drives are present.

Press any key to enter the configuration utility.

Probable Cause:

The controller preserves the dirty cache from a virtual disk if 

the disk becomes offline or is deleted because of missing physical disks.

This preserved dirty cache is called pinned cache, and is preserved until 

you import the virtual disk, or discard the cache.

Corrective Action:

Use the utility to import the virtual disk or discard the preserved cache. 

For the steps used to manage preserved cache, see Managing Preserved Cache.
  

相关文章

服务器端口转发,带你了解服务器端口转发
服务器开放端口,服务器开放端口的步骤
产品推荐:7月受欢迎AI容器镜像来了,有Qwen系列大模型镜像
如何使用 WinGet 下载 Microsoft Store 应用
百度搜索:蓝易云 – 熟悉ubuntu apt-get命令详解
百度搜索:蓝易云 – 域名解析成功但ping不通解决方案

发布评论